Capacity |
Cold |
kW |
14.00 |
Warm |
kW |
15.50 |
Power supply |
~380-415V/50РHz/3Ph |
Rated input |
Cold |
kW |
5.1 |
Warm |
kW |
4.5 |
Current rate |
Cold |
A |
8.80 |
Warm |
A |
7.80 |
Energy efficiency |
EER (Cold) |
kW/kW |
2.75 |
C.O.P. (Warm) |
kW/kW |
3.44 |
Air capacity |
m³/h |
2400 |
Nominal pressure |
Indoor unit |
Pа |
50 |
Pressure range |
Indoor unit |
Pа |
0-125 |
Sound-pressure level |
Indoor unit/Outdoor unit |
dB(А) |
55/53/49/45/59 |
Refrigerant coolant type |
R410a |
Refrigerant coolant |
kg |
4.0 |
Dimensions (width/height/depth) |
Indoor unit/Outdoor unit |
mm |
1340х750х350 / 958х412х1349 |
Weight |
Indoor unit/Outdoor unit |
kg |
56/114 |
Operational temperature range |
Cold |
°C |
-15 ... +48 |
Warm |
°C |
-20 ... +24 |
Fluid pipeline diameter |
mm/inch |
9.53/ 3/8" |
Gas pipeline diameter |
mm/inch |
15.88/ 5/8" |
Maximum pipeline level difference |
m |
30 |
Maximum pipeline length |
m |
50 |
Number of the interblock strands (for control) |
2*1.0 – up to 20 m long |
Main power supply area |
Outdoor |
Number of strands (power supply) |
Indoor unit |
|
3(Ø1.0 mm) |
Outdoor unit |
|
3(Ø2.5 mm) |
Factory freon fill (for the number of running meters) |
r.m. |
5 |
Quantity of freon per one running meter (surplus. for one running meter) |
gramm/r.m. |
60 |
SEER/SCOP |
5.6/3.8 |