Capacity |
Cooling |
kW |
5,00 |
Heating |
kW |
5,50 |
Electric power supply |
~220-240 V/50 Hz/1 Ph |
Rated input |
Cooling |
kW |
1,55 |
Heating |
kW |
1,60 |
Energy performance |
Cooling |
EER |
3,23 |
Heating |
COP |
3,44 |
Air flow |
Indoor unit |
m³/h |
850 |
Sound-pressure level |
Indoor unit |
dB (A) |
44/42/39/36 |
Outdoor unit |
dB (A) |
53 |
Type of refrigerant coolant |
R32 |
Refrigerant coolant type |
kg |
1,00 |
Weight |
Indoor unit |
kg |
26 |
Outdoor unit |
kg |
39 |
Operational temperature range |
Cooling |
°C |
-20~48 |
Heating |
°C |
-20~24 |
Liquid pipeline diameter |
mm/inch |
6,38/1/4" |
Gas pipeline diameter |
mm/inch |
12,70/1/2" |
Maximum pipeline level difference |
m |
20 |
Pipeline maximum length |
m |
35 |
Number of interblock strands (for control) |
mm² |
2х0,75 |
Main power supply area |
Outdoor unit |
Number of the strands
(power supply) |
Indoor unit |
3 (∅ 1,0mm²) |
Outdoor unit |
3 (∅ 1,5mm²) |
Factory Freon fill ( for the number of the running meters) |
m |
5 |
Freon per one running meter (surplus. for one running meter) |
g/m |
16 |
SEER/SCOP |
6,10/4,00 |
Energy performance class |
А++/А+ |